KEEP YOUR X-RAY COMPLIANT, ACCURATE & READY

X-ray equipment plays an important role in diagnosis and patient care. An Equipment Performance Evaluation, or EPE, helps verify that your equipment is operating properly and meeting Texas requirements.

What Is an EPE?

It is more than just an inspection. The evaluation verifies that your

x-ray is producing radiation appropriately and operating within required performance standards. Texas DSHS requires the results to include actual measurements and a pass/fail determination for the requred tests.

When Does My Dental Office
Need an EPE?

Texas requirements for dental X-ray equipment:

ChatGPT Image Oct 13, 2026, 10_14_20 AM.png

New Installation
Within 30 Days

An EPE is required within 30 days after the initial installation of a dental radiation machine.

ChatGPT Image Oct 13, 2026, 10_36_30 AM-2.png

Reinstallation
Within 30 Days

If an X-ray machine is relocated and reinstalled, an EPE is required within 30 days. 

ChatGPT Image Oct 6, 2026, 12_42_03 PM-2.png

Certain Repairs
Within 30 Days 

An EPE may be required after repair of components that affect radiation output, such as the timer, tube, or power supply.

ChatGPT Image Oct 13, 2026, 03_51_18 PM-1.png

Routine EPE
Every 4 Years

Dental intraoral, panoramic, cephalometric X-ray systems require an EPE at intervals not exceeding four years.

ChatGPT Image Oct 13, 2026, 10_36_32 AM-5.png

Dental CBCT
Annually

Dental CT/CBCT systems require an EPE annually, with the interval not exceeding 14 months.

What Does an EPE Test?

Your evaluation includes testing of key X-ray performance factors.

ChatGPT Image Oct 13, 2026, 12_34_18 PM-1.png

Timer Accuracy

Verifies proper exposure

timing and operation.

​

Carestream CS 9600 Dental Imaging Scanner.png
ChatGPT Image Oct 13, 2026, 12_34_22 PM-4.png

Tube Stability

Verifies that the X-ray tube remains properly positioned and stable during exposure. 

ChatGPT Image Oct 13, 2026, 12_34_20 PM-2.png

Exposure Reproducibility

Confrims repeated exposures 

remain consistent.

ChatGPT Image Oct 13, 2026, 12_34_24 PM-5.png

Collimation

Evaluate proper limitation of the X-ray field.

ChatGPT Image Oct 13, 2026, 12_34_21 PM-3.png

kVp Accuracy

Checks whether the selected kilovoltage matches the unit's actual output. 

ChatGPT Image Oct 13, 2026, 12_34_26 PM-6.png

Entrance Exposure (Air Kerma)

Measure radiation output against applicable limits.

Blue Calendar Circle Icon.png

Is Your X-Ray EPE Coming Due?

Don't wait until an inspection to find out your dental X-ray equipment is overdue for evaluation. We help dental practices with affordable prices stay compliant and on schedule with their EPE requirements. 

Schedule an EPE

What You Receive From Your EPE?

Clear results, Proper documentation.

ChatGPT Image Oct 13, 2026, 12_02_21 PM-1.png

Recorded
Measurements

Numerical results for each required test.

EPE_Pass_Fail_Results_Icon.png

Pass or Fail
Results

Clear pass or fail results for each tests. 

EPE_Equipment_Requiring_Correction_Icon.png

Required
Corrections

Identification of any equipment that requires correction.

EPE_Documentation_for_Compliance_Icon.png

Documentation for
Compliance

Complete EPE report to maintain with your X-ray compliance records.